Product Overview: The ROSSMAX AS175 Valved Holding Chamber is a cutting-edge device meticulously designed to work harmoniously with metered dose inhalers (MDIs). Engineered to deliver aerosol medication directly to your lungs under the guidance of licensed healthcare professionals, this chamber ensures optimal treatment outcomes. Whether at home, in hospitals, or clinics, this versatile chamber accommodates diverse patient populations. Discover the ease of use, comfort, and reliability that the ROSSMAX AS175 Valved Holding Chamber brings to your inhalation therapy.
Key Characteristics:
- High Efficiency One-Way Valve: Experience effortless inhalation and exhalation through the high-efficiency one-way valve, enhancing medication delivery accuracy.
- Universal Backpiece Compatibility: Designed to accommodate all commonly prescribed MDIs, this chamber guarantees a seamless fit for your specific medication regimen.
- Anti-Static Spacer: The anti-static spacer technology prevents drug adherence to the chamber's walls, ensuring maximum drug delivery efficiency.
- Soft and Flexible Silicone Mask: The soft and flexible silicone mask offers a comfortable and reliable seal, promoting ease of use and patient compliance.
- Portable Design: Take your therapy on the go with the compact and portable design, allowing for easy handling and transport.
- Easy Maintenance: Disassemble and reassemble effortlessly for thorough cleaning, maintaining the device's hygiene and functionality.
- Mouthpiece Cap: Protect the mouthpiece from dirt and debris when not in use, ensuring a clean and effective medication delivery.
- Latex-Free and BPA-Free: This product is constructed without latex and is BPA-free, prioritizing patient safety and well-being.
- Facemask Options: Choose from various facemask sizes to cater to different patient needs:
- Small Facemask: 0-18 months
- Medium Facemask: 12 months – 5 years
- Large Facemask or Mouthpiece: 5 years and above
- Chamber Volume: With a spacious 175ml chamber volume, ensure accurate and consistent medication delivery.
- Single Patient Use: The ROSSMAX AS175 is intended for single patient use only, ensuring optimal hygiene and safety.
Cautions and Usage Guidelines:
- Replace the device after one year of use.
- Adhere to the recommended cleaning process; avoid boiling, sterilizing, or dishwasher washing.
- Strictly follow physician's dosage instructions.
- Keep the chamber out of children's reach; it is not a toy.
- Assistance from adults or doctors is necessary for children and infants to operate the device.
Notes:
- The chamber's antistatic material prevents medication adhesion to the walls.
- The device is latex-free.
- Designed for single patient use only.
- Store the device or mask in a clean place or a clean polybag when not in use.
- Storage/Operating Conditions: 5ºC-40ºC (41ºF-104ºF); 15-95% RH
Cleaning Instructions: For optimal performance and safety, clean the chamber and mask once a week. Do not tamper with or remove the valve during cleaning.
Invest in your health and well-being with the ROSSMAX AS175 Valved Holding Chamber – Your Partner in Precise Aerosol Medication Delivery.
Disclaimer: Always consult a licensed healthcare professional before using medical devices. This product description is for informational purposes only and not a substitute for medical advice.
Resources:
Returns Policy
1. Prior Approval Required: All returns must be approved by us prior to sending any goods back. Please contact us to obtain a return authorization before returning any items.
2. Claims for Issues: Claims for short delivery, incorrect supply, or damaged goods during transport must be made within 7 days of the delivery date. Please inspect your goods upon receipt and notify us immediately if there are any issues.
3. Return Conditions: We do not accept returns for any reason other than a faulty product. This includes, but is not limited to, returns due to change of mind or incorrect orders.
4. TGA Duties: For products regulated by the Therapeutic Goods Administration (TGA), returns must comply with relevant TGA regulations and guidelines. Any return of TGA-regulated products will be subject to additional conditions as required by law.
5. Return Shipping Costs: Return shipping costs are the responsibility of the buyer unless otherwise agreed upon in the case of faulty products.
6. If you have any questions regarding returns or need assistance, please contact us before proceeding with the return process.
Shipping
1. Responsibility for Delivery: Once your parcel is with the courier service, it is beyond our control. We are not responsible for any loss, damage, or delivery issues that may occur once the parcel is in the possession of the courier.
2. Safe Place Deliveries: If the courier decides to leave your parcel in a location they deem as a “safe place,” we cannot be held liable for any issues that arise from this decision.
3.Signature Option: For added security, you may request a signature upon delivery for an additional fee of $3.00 per carton. This option ensures that your parcel will not be left unattended and, if no one is available to receive it, will be taken to the nearest post office or depot for pickup.
4. Tracking Information: Tracking numbers will be provided to you via email. It is the buyer’s responsibility to monitor the progress of their parcel using the tracking information provided.
5. Buyer’s Responsibility: Any discrepancies or issues with the delivery must be followed up with the respective courier service by the buyer.