NEEDLE FREE IV CONNECTOR SWABABLE HALKEY ROBERTS VALVE INTRAVENOUS

NEEDLE FREE IV CONNECTOR SWABABLE HALKEY ROBERTS VALVE INTRAVENOUS

MDevices

HR2452-S

$3.50
-
+
$3.50

HALKEY ROBERTS INTRAVENOUS NEEDLE FREE SWABABLE VALVE

NO MORE NEEDLE STICK INJURIES!

SOURCE - SUPPLY - PROTECT

Another Quality Product from the Medical Specialist Company Solmed.

Mates securely with all standard Luer syringes and connectors providing a hermetic seal between syringe luer tip and valve.

  • Polycarbonate - clear.
  • Priming volume: 0.09ml
  • Sterile individually Packed
  • TGA listed ARTG 172521
  • 7 Day Microbial Challenge (Valve passed 140 activations over 7 Days using Hospital protocols without any organisms after correct swabbing).
  • Use sterile alcohol wipe for swabbing before use.
  • Passed all test for Flushing.
  • Exceeded 200 Activation test protocols and retained back pressure performance.
  • All materials are Gamma resistant, ISO 10993 compliant, DEHP-free and latex-free.
  • Luer fittings are compatible with American National Standards for luer and taper fittings under
    ANSI/HIMA MD70.1-83 and ISO 594.
  • Halkey-Roberts new swabable luer valves were developed as needlefree injection ports in IV applications.
    They are designed to aspirate or inject fluids on demand. The valves allow multiple usage and require no cap.
    Valve stems and bodies will mate securely with all standard luer syringes and luer connectors.
  • Flow Rate @ 1 psi: 360ml/minute (21,000ml/hr @ 30 inch height),
    Flow Rate @ 3 psi: 600ml/minute,
    Flow Rate @ 5 psi: 750ml/minute

SEE TECHNICAL SPECIFICATIONS

Returns Policy

There is a 30 day return on any faulty products. To be eligible you must return items at your cost. We guarantee that any product found to be faulty supplied by us, will be accepted for return and we will refund all costs associated with the returned item. Statutory Warranties and conditions of Sale apply in Australia under consumer law for all products supplied by Australian Companies.
IMPORTANT NOTE: Should any faulty item be a TGA Registered Medical Product or Device, we are required to submit a report to the Registered Manufacturer in accordance with the TGA Legislation. This is a way of ensuring that any device is safely tracked and monitored for safety. We may ask you a few questions and we are required to verify any fault. All standard State & Federal Warranty Conditions apply.

Shipping

SOLMED only supplies to Australian Addresses.
Solmed dispatches all goods via Australia Post or TNT whichever is deemed suitable. We post to all addresses in Australia including Post Office Boxes. Tracking will be notified on Parcels where applicable. Solmed will advise if any product is not available and offer either a substitute, refund or back order.